Tag: incineration

Kenya: How Toxic and Infectious Medical Waste Is Harming Citizens

A visit to the hospital does not usually reveal what happens at the back. It is here where discarded blood…

The other day in the waste incineration plant

Recently a dream came true for me. I had the opportunity to participate in a guided tour through the waste…

Incinerator Primary Combustion Chamber

HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal for military and civil camps and remote locations where infrastructure is scarce. Incineration is the most obvious solution for total destruction of municipal waste, avoiding all the direct and indirect risks associated with other disposal methods.Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same place where it was generated to avoid cross-contamination risk and to keep waste treatment costs at acceptable level. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201   Website: www.hiclover.com  Email: [email protected]Email: [email protected]  

Open tray burning wins out over closed incinerator for M6 propellant at Camp Minden

The first of many public meetings concerning the disposal of more than 15 million pounds of M6 propellant at Camp…

MEDICAL WASTE INCINERATOR (50 C 60kg/hr)

Medical Waste Incinerator, 50 to 60 Kg/hrSupport Health Sector Support ProjectPoint of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals1.    General DescriptionSupply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General and Pathological waste in a safe and clean environment.  The unit shall consist of two chambers and operate on the principal of controlled air and temperature. The unit shall consist a particulate remover (scrubbers) as stipulated in waste management regulations, 2006 (Legal notice NO. 121 of 29th September, 2006).  The Unit shall be fully automatic and controlled by an automatic electronic controlled system except loading system which shall be manual.  The unit shall be capable of incinerating between 50 to 60 kg of solid medical waste per hour.  It shall be constructed from mild or aluminized steel lined with refractory material.Main unit Application For incineration, general and pathologicalCapacity   50 C 60 kg/h burn rateType Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unitOperating time                Minimum 8 hours dailyOperating temperature     From 850 0C to 1200 0C, Automatic controlledResidual Ash                    5 to 10%    3.2     Primary ChamberConstruction Constructed from heavy duty mild or aluminized  steel Orequal and approved equivalentInsulation material            Refractory material lining similar or equal to calcium Silicate and hot face combination of heavy duty brickworkInternal Construction        Fixed hearth type complete with gratings, concave bottomand charging door, lined with refractory materialCharging Door                   Suitable for manual loading of wastes and with smooth Dear seal equivalent of Ceramic seals with hinges.Door Lock                          Automatic, Electric typeAsh removal door    Provided, for removing resultant bottom ash leftovers                              from the Primary chamberGratings   ProvidedLoading Manual loading of wastePrimary Burner                        Fully automatic, with fuel, temperature and speed controls with ignition system, flame detector, Air fan complete with safety features, flame failure,  Diesel fired fuel injector type and Flange mounted                                                                                                    Blower Provided. For supplying excess combustion air through the distribution system with speed control systemTemperature…

An Unexpected Ebola Infrastructure Problem: Waste

Patients with this debilitating virus produce 440 gallons of medical waste daily, including instruments, gowns, gloves, body fluids, sheets, mattresses…

MEDICAL WASTE INCINERATOR (50 C 60kg/hr)

Medical Waste Incinerator, 50 to 60 Kg/hrSupport Health Sector Support ProjectPoint of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals1.    General DescriptionSupply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General and Pathological waste in a safe and clean environment.  The unit shall consist of two chambers and operate on the principal of controlled air and temperature. The unit shall consist a particulate remover (scrubbers) as stipulated in waste management regulations, 2006 (Legal notice NO. 121 of 29th September, 2006).  The Unit shall be fully automatic and controlled by an automatic electronic controlled system except loading system which shall be manual.  The unit shall be capable of incinerating between 50 to 60 kg of solid medical waste per hour.  It shall be constructed from mild or aluminized steel lined with refractory material.Main unit Application For incineration, general and pathologicalCapacity   50 C 60 kg/h burn rateType Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unitOperating time                Minimum 8 hours dailyOperating temperature     From 850 0C to 1200 0C, Automatic controlledResidual Ash                    5 to 10%    3.2     Primary ChamberConstruction Constructed from heavy duty mild or aluminized  steel Orequal and approved equivalentInsulation material            Refractory material lining similar or equal to calcium Silicate and hot face combination of heavy duty brickworkInternal Construction        Fixed hearth type complete with gratings, concave bottomand charging door, lined with refractory materialCharging Door                   Suitable for manual loading of wastes and with smooth Dear seal equivalent of Ceramic seals with hinges.Door Lock                          Automatic, Electric typeAsh removal door    Provided, for removing resultant bottom ash leftovers                              from the Primary chamberGratings   ProvidedLoading Manual loading of wastePrimary Burner                        Fully automatic, with fuel, temperature and speed controls with ignition system, flame detector, Air fan complete with safety features, flame failure,  Diesel fired fuel injector type and Flange mounted                                                                                                    Blower Provided. For supplying excess combustion air through the distribution system with speed control systemTemperature…

Incinérateur P déchets médicaux à Atmosphere contrôlé conçu pour À 'incinération des déchets biomédicaux

Incinérateur de déchets médicaux à air contrôlé conçu pour l’incinération des déchets biomédicaux générés dans un centre de traitement du…

Another challenge: disposing of waste

A single Ebola patient treated in a U.S. hospital will generate eight 55-gallon barrels of medical waste each day. Protective…

Incinerator with Capacity of destruction in weight: 60 Kg/h.

Capacity of destruction in weight: 60 Kg/h. It should be able to operate not less than 10 hours/day This incinerator…